BLOOD MONITOR PRESSURE METER
Blood
monitor pressure meter is intended for systolic pressure, diastolic pressure
and pulse rate measurement in medical institutions and at home. This
meter does not require special skills in order to be operated and can
be used for self-measuring.
Sphygmomanometer is said to be the superior blood pressure
meter ever built. It is the result of extensive research and
incorporated with fine, accurate, durable materials available.
This medical equipment is designed to provide physicians with accurate
and dependable blood pressure measurements along with minimal care and
maintenance.
This mercurial sphygmomanometer blood monitor pressure meter desk
model has a mercury filled glass tube with easy-to-read metal scale and
calibrated from 0mm.Hg to 300mm.Hg.
This delivers a scientific precise accuracy. Cuff size, index and range
markings are indicated along with the artery indicator and gauge
holder. It is calibrated with two tube latex bladder.
It comes on package of aluminum alloy, lightweight, strong and portable
caring case.
A wrist type blood pressure monitor is essential to knowing
your health and is appropriate for exercise program. It is in
lightweight unit placed on the wrist and pressing a single button.
Systolic and diastolic pressures is accurately displayed in seconds on
its large, easy-to-read display, also displays heart rate and mean
arterial pressure. It includes a 30-reading memory and auto power off
with a handy carrying bag.
A current model of a blood monitoring device is the ultra-low power flash blood
monitor pressure meter.
This device can work under PC control transferring internal tables and signal
samples for analysis and algorithm improvements.
The equipment stays in low power mode 3 between measurements.
The LCD test is displayed when the I/O button is pressed and prepares for measurement.
Its cuff is placed around the user’s hand and connected to the meter via the attached
air tube.
LCD displays current pressure value during measurement.
Air compressor inflates the cuff up to specified maximum pressure and stops.
Air progressively goes out through the vent hole.
Heart icon blinking and buzzer sound indicates each detected pulsation, at the
same time measuring pulse rate.
The measurement stops at below diastolic and pulsation parameters are used to
calculate systolic and diastolic pressures.
It automatically increment by 40 mmHg if the maximum pressure appears insufficient
and thus the cycle repeats.
Archive data can be viewed by the user by pressing and holding the I/O button.
Start button then scrolls through the archive. Then, press and hold of the I/O
button cancels archive reading.
Shortly pressing the button or no buttons pressed during 3 minutes turns off the
device.
|